I-Industrial Ethernet switch (i-industrial switch for short) luhlobo lwezixhobo zothungelwano ezingabizi kakhulu ezibonelelwe ngokukodwa ukuhlangabezana neemfuno zezicelo zemizi-mveliso eziguquguqukayo.Ngokwemfuno yokwenene yolawulo lwamashishini, utshintsho lwemizi-mveliso lusombulula iingxaki zobuchwepheshe ezifana nonxibelelwano lwexesha langempela, ukusebenza kokufumaneka kwenethiwekhi kunye nokhuseleko.Xa kuthelekiswa nokutshintsha kwezorhwebo eziqhelekileyo, utshintsho lwezoshishino lufuna ngakumbi kuyilo kunye nokukhethwa kwamacandelo, kwaye lunokulungelelaniswa ngcono kwiimfuno zesayithi elibukhali lendawo yokulawula i-industrial.Iswitsha yolawulo lwezintlu ezimbini (ukuxhasa umsebenzi we-PoE), ngokuzimeleyo iphuhliswe yi YFC CF-HY4008G series switsha industrial, has 4/810/100/1000Mbps adaptive RJ 45 port and 2/8 SFP gigabit light port.Ichweba ngalinye le-RJ 45 lixhasa i-MDI / MDIX i-flipping ezenzekelayo kunye nomsebenzi wokuhambisa isantya somgca.Izibuko ze-1-8 zinokuxhasa ukunikezelwa kwamandla e-POE, landela i-IEEE802.3af / kumgangatho, ingasetyenziselwa njengesixhobo sombane we-Ethernet, inokubona ngokuzenzekelayo kwaye ichonge izixhobo zokufumana amandla ezidibana nomgangatho, kwaye zibonelele ngenethiwekhi. intambo.Ayisiyiyo kuphela ngoyilo lwesekethe yokupholisa i-fan, ubushushu obubanzi bendawo yokusebenza, itekhnoloji ephezulu yokhuseleko, njengokumelana nokungcangcazela, ubushushu obuphezulu / obuphantsi, uthuli, ukhuseleko lombane, kodwa kunye nendlela edibeneyo, utshintshiselwano, ukhuseleko kunye nezinye iiprotocol ezityebileyo, kunye nenkxaso. itekhnoloji ye-Ethernet yokukhusela i-multi-ring ring (ERPS), ephucula kakhulu ukuguquguquka kwenethiwekhi, kunye nokwandisa ukuthembeka kunye nokhuseleko lwenethiwekhi yezoshishino.Xa kuthelekiswa nokutshintshwa kwemizi mveliso yemveli, i-YOFC CF-HY4008G VP series inikezela ngesiseko esinamandla, esilula ukuyisebenzisa kunye nesikhuselekileyo esinokuhlangabezana nezidingo zokuthunyelwa kwisixeko esikhuselekileyo, ukuthutha okuhlakaniphile, ukubeka iliso ngaphandle kunye nezinye iindawo ezinzima.
◎ iimpawu zokusebenza
Uyilo lwehardware ekumgangatho ophezulu, kunye nokusebenza kwezixhobo ezizinzileyo
Uyilo lwehardware ekumgangatho ophezulu.Landela ukucaciswa koyilo lweshishini, wamkele umzi-mveliso omkhulu wamazwe ngamazwe oqolileyo webakala leshishini, i-CPU yomgangatho wokusebenza okuphezulu, imodyuli yomgangatho weshishini kunye neqokobhe le-aluminium alloy, ukuqinisekisa umgangatho womgangatho weemveliso.
Ukusebenzisa uyilo lwesekethe yokuchitha ubushushu obungaphantsi kwefeni, inkxaso-40 ~ 85℃ iqondo lobushushu lendawo yokusebenza, inqanaba lokhuselo lwe-IP40, amandla ombane okhuselo lombane 8KV, uyilo lonikezelo lwamandla okukhusela ukungcangcazela, uphazamiseko lwe-electromagnetic elikumgangatho okwinqanaba eline, ukumelana nempembelelo kunye nokungcangcazela, izixhobo. inokusebenza ngokuzinzileyo nangokuthembekileyo nakwimekobume erhabaxa.
Imisebenzi yenethiwekhi etyebileyo kunye neempawu zokhuseleko
Inkxaso ye-VLAN, i-STP / RSTP / i-MSTP ejikelezayo yomthi, i-ERPS Ethernet iteknoloji yokukhusela i-multiring, i-multicast, isibuko se-port, i-QoS, ukhuseleko lwe-port, kunye nokunyanzeliswa kwesaqhwithi;Ixhasa iprothokholi yothungelwano enemigangatho emithathu efana nendlela engatshintshiyo.
Ngokusebenzisa iindlela ezahlukeneyo zokhuseleko lwangaphakathi zinokuthintela ngokufanelekileyo kwaye zilawule ukusasazeka kwentsholongwane kunye nohlaselo lwetrafikhi yenethiwekhi, ukulawula abasebenzisi abangekho mthethweni ukusebenzisa inethiwekhi, ukuqinisekisa inethiwekhi yokulungelelanisa yabasebenzisi abasemthethweni, njenge-port static kunye nokubopha ukhuseleko oluguqukayo, ukuhlukaniswa kwezibuko, iintlobo ezahlukeneyo zehardware. Ulawulo lwe-ACL, umda wesantya se-bandwidth esekelwe kwi-data flow, isibophelelo sokulawula ukufikelela komsebenzisi, njl., ukuhlangabezana nolawulo lwakho lokhuseleko lwenethiwekhi yokufikelela kwisixhobo.
I-Flexible networking, ulawulo olulula
Ikwaxhasa imowudi yothungelwano lwenkwenkwezi yemveli kunye ne-Ethernet multi-loop yokukhusela itekhnoloji (ERPS) ukuphumeza uthungelwano lwe-annular.Le ndlela yothungelwano inokuthembeka okuphezulu kokungafuneki.Emva kokuba enye i-node ye-loop ihluleka, idatha ingathunyelwa ukusuka kwelinye icala, kwaye ixesha lokutshintsha liyi-20ms.Kwangaxeshanye, xa kuthelekiswa nenethiwekhi yeringi yokonga ngakumbi ifayibha ebonakalayo, inokukongela iindleko ezithile zokwakha.
Ifom ye-gigabit flexible port electric port + light port (engaphinda isetyenziswe) ilungele abasebenzisi ukuba bakhethe ngokuguquguqukayo ifom yokudibanisa ngokuhambelana nolwakhiwo lwenethiwekhi.Ngexesha elifanayo, umgca womyalelo we-CLI wendabuko kunye ne-Web graphical interface yoqwalaselo utshintshiselwano, ngaphandle kwesidingo sokuqonda umgca womyalelo onzima kunye neenkqubo zokulinganisa i-terminal, ukuvumela ukutshintshwa koqwalaselo olulula nolukhawulezayo, ngaloo ndlela ukunciphisa ubunzima bokuthunyelwa.
◎ izalathisi zobugcisa bemveliso
ipharamitha yobugcisa | inkcazo yeparametric | ||
imodeli yemveliso | CF-HY4008G-SFP | CF-HY4008GP-SFP | |
Izibuko ezizinzileyo | 810 / 100 / 1000M izibuko zombane eziguqukayo | 810 / 100 / 1000M izibuko ze-PoE eziguqukayo | |
Izibuko ezine zokukhanya ze-1,000 BASE-XSFP | Izibuko ezine zokukhanya ze-1,000 BASE-XSFP | ||
Umlomo wokulawula | Izibuko eli-1 leConsole | ||
umthamo wotshintshiselwano | 20Gbps | ||
Ireyithi yokuthumela ipakeji | 14.88Mpps | ||
Uluhlu lweedilesi ze-MAC | 16K | ||
Ipakeji ye-cache | 12M bit | ||
Ukudityaniswa kwezibuko | Ixhasa i-GE port aggregation | ||
Ixhasa i-2.5GE port aggregation | |||
Ixhasa ukudityaniswa okumileyo | |||
Ukuxhasa udibaniso oluguquguqukayo | |||
Iimpawu zePort | Ixhasa i-IEEE802.3x ulawulo lokuhamba | ||
Inkxaso yezibalo zezithuthi zezibuko | |||
Umsebenzi wokwahlulwa kwezibuko | |||
Ixhasa ukucinezelwa kwesaqhwithi ngokusekelwe kwipesenti yezinga lezibuko | |||
PoE | / | Inkxaso ye802.3af(15.4W),802.3at (30W) | |
Inkxaso 1,2 +, 3,6-unikezelo lwamandla | |||
Inkxaso iyahambelana nezixhobo ezingezizo eziqhelekileyo zePD | |||
Inkxaso yolawulo lwePoE | |||
VLAN | Inkxaso yendlela yofikelelo | ||
Inkxaso yeepateni zomzila | |||
Inkxaso yendlela yomxube | |||
Ukuhlelwa kweVLAN | VLAN esekwe kwiMac | ||
IP esekelwe VLAN | |||
Protocal Based VLAN | |||
QinQ | I-QinQ esisiseko (i-QinQ esekwe ePort) | ||
Umfanekiso wesipili sezibuko | Umfanekiso wesipili esi-Multi-to-one (Isibuko sesibuko) | ||
Umgangatho wesibini ring isivumelwano womnatha womnatha | Inkxaso ye-STP, i-RSTP, kunye ne-MSTP | ||
Ixhasa iprotocol ye-G.8032 ERPS, ixhasa iluphu enye, iilophu ezinxulumene nezinye iiluphu (Iringi yeSub) | |||
I-DHCP | Inkxaso ye-DHCP Client | ||
Inkxaso ye-DHCP Snooping, xhasa i-port trust setting | |||
Usasazo lweqela | IGMP V1,V2,V3 | ||
I-IGMP yokujonga | |||
ACL | IP Standard ACL (IP Standard ACL) | ||
MAC Extension ACL (MAC yandisa ACL) | |||
IP Extension ACL (IP extension ACL) | |||
QoS | Inkxaso yokumakishwa kwe-QoS, imephu ephambili (iKlasi yeQoS, ukuMakisha) | ||
Inkxaso ye-SP, ukucwangciswa komgca we-WRR (Inkxaso ye-SP, ukucwangciswa komgca we-WRR) | |||
Umda wesantya sokungena (I-Port-based Rate-limit ye-Ingress Port-based) | |||
Umda wesantya sokuphuma (I-Egress Port-based Rate-limit) | |||
I-QoS esekwe ngokuqukuqelayo (iQoS esekwe kuMgaqo-nkqubo) | |||
Iimpawu zokhuseleko | I-Dot yenkxaso ye-1 x, ukuqinisekiswa kwe-port yenkxaso, ukuqinisekiswa kwe-mac, inkonzo ye-RADIUS | ||
Inkxaso yokhuseleko lwezibuko | |||
Inkxaso ye-ip source guard, IP / Port / MAC umsebenzi wokubopha | |||
Inkxaso yokukhangela i-arp, ixhasa ukucoca umyalezo ongekho mthethweni we-arp | |||
Ukwahlukaniswa kwezibuko | |||
Ulawulo nolondolozo | Xhasa i-LLDP yekhonkco lokufumana iprotocol | ||
Inkxaso yolawulo lomsebenzisi, inkxaso yokungena ngemvume | |||
Inkxaso ye-SNMPV1 / V 2 C/V3 | |||
Inkxaso yolawulo lwewebhu, i-HTTP 1.1, kunye ne-HTTPS | |||
Inkxaso yelog yenkqubo yeSyslog, i-alamu ehleliweyo | |||
inkxaso RMON | |||
Inkxaso yokubeka iliso lobushushu | |||
I-Ping, iTracert iyaxhaswa | |||
Inkxaso yokubeka iliso kwimodyuli yokukhanya (DDM) | |||
Inkxaso yoMthengi we-TFTP | |||
Inkxaso yeSeva yeTelnet | |||
Inkxaso yeSSH Server | |||
Inkxaso ye-TFTP, i-WEB yokulayisha kunye nokuphucula | |||
Inkxaso yolawulo lwe-IPv6 | |||
umyinge wamagqabantshintshi mm | 172 x 142x 54mm (ubude * ububanzi * ukuphakama) | ||
ukuphazamiseka kwe-electromagnetic | IEC 61000-4-2 (ESD) iNqanaba 4 (8K/15K)IEC 61000-4-3 (RS) iNqanaba 3 (10V/m) IEC 61000-4-4 (EFT) iNqanaba 3 (1V/2V) IEC 61000-4-5 (Utyando) iNqanaba 4+ (6KV/2KV) IEC 61000-4-6 (CS) iNqanaba 3 (10V/m) IEC 61000-4-8 (PFMF) Level4 (30A/m) IEC 61000-4-11 (DIP) Level3 (10V) | ||
umthombo | igalelo leDC DC;igalelo lamandla amabini angafunekiyo | ||
Uluhlu lombane olulinganisiweyo: 12-57V | |||
ukuchithwa kwamandla | Ukusetyenziswa kwamandla omatshini wonke yi-5W | Ukusetyenziswa kwamandla omatshini wonke (ngaphandle komthwalo we-PoE) yi-5W | |
Ukusetyenziswa kwamandla ngokubanzi (umthwalo ogcweleyo we-PoE) yi-60W | |||
ubushushu | Ubushushu bokusebenza: -40 ℃ -80 ℃ | Ubushushu bokusebenza: -40 ℃ -70 ℃ | |
Ubushushu bokugcina: -40 ℃ -85 ℃ | Ubushushu bokugcina: -40 ℃ -80 ℃ | ||
ukufuma | Ukufuma okusebenzayo: 10% -90% RH | ||
Ukugcinwa kokufuma: 5% -95% RH |
◎ ubungakanani bembonakalo yemveliso
Ubude x, ububanzi x, ubude (mm): 172 x 142x 54mm
◎ umzobo wesicelo semveliso
UThutho olukrelekrele
Iikhamera ezintathu zokucupha zisekwe kwiindlela ezine zendlela kwi-intersection nganyeCF-HY2004GVP-SFPNikeza iziteshi zothumelo lwemifanekiso kunye nevidiyo kwiikhamera ezintathu zokuhlangana, kwaye usebenzise enye kwenye i-intersectionCF-HY8008GVP-SFP.Idatha idluliselwa kwi-intersection nge-gigabit optical fiber, kunye nokulawulwa kokukhanya komqondiso, idatha yokubeka iliso kwendalo kunye nedatha yevidiyo isendaweniCF-HY8008GVP-SFPAEmva kokuguqulwa, idluliselwa kwiziko lokubeka iliso nge-fiber optical, kwaye emva koko idluliselwe kwi-fiber optical. Umbindi wesixeko ngokusebenzisa inethiwekhi ekhoyo yomqolo.
Isixeko esikhuselekileyo
Ukutshintsha kwesikhululo samapolisa kunye nokutshintsha kokufikelela okudlula kwi-intersectionCF-HY4T8024G-SFFPTogether, benza iringi yokukhusela i-fiber eyodwa.Inokugcina izixhobo zefiber optical.Iprotocol ye-ERPS Ethernet yokhuseleko lomnatha isetyenziswa kwiringi.Ukutshintsha ngokukhawuleza kwe-<=20ms kunokufezekiswa.
◎ ulwazi lwemodeli
Odola ulwazi lwale mveliso | ||
imodeli | inkcazelo | izimvo |
CF-HY 4008G-SFP | Izibuko ezine ze-gigabit SFP zokukhanya, ezisibhozo i-10 / 100 / 1000 izibuko eziguqukayo, i-DC 12-52V, i-L2 layers | efunekayo |
CF-HY 4008GP-SFP | Izibuko ezine ze-Gigabit SFP zokukhanya, ezisibhozo i-10 / 100 / 1000 i-adaptive poE port, DC 48-57V, L2 layers | efunekayo |
CF-HY 4008GV-SFP | Izibuko ezine ze-Gigabit SFP zokukhanya, ezisibhozo i-10 / 100 / 1000 izibuko eziguqukayo, i-DC 12-52V, i-L2 + iileya | efunekayo |
CF-HY 4008GVP-SFP | Izibuko ezine ze-gigabit SFP ukukhanya, ezisibhozo 10 / 100 / 1000 adaptive PoE amazibuko, DC 48-57V, L2 + layers | efunekayo |
CF-GE-MM850 | Imodyuli ye-Optical SFP 1.25 GMMF ifayibha kabini LC (850nm, LC, 550m) | ekhethiweyo |
CF-GE-SM1310-20 | Imodyuli ye-Optical SFP 1.25 G SMF ifayibha kabini LC (1310nm, LC, 20km) | ekhethiweyo |
CF-GE-SM1310-A20 | I-BIDI Optical Module SFP 1.25 G SMF ifayibha enye LC (TX1310 / RX1550nm, LC, 20km) | ekhethiweyo |
CF-GE-SM1550-B20 | I-BIDI Optical Module SFP 1.25 G SMF ifayibha enye LC (TX1550 / RX1310nm, LC, 20km) | ekhethiweyo |
HDR-15-12 | 15W/1.25A IsiKhokelo sohlobo lukaloliwe 12V DC unikezelo lwamandla, jikelele 100 ukuya 240V AC igalelo, ubushushu bokusebenza-20 ~ 70 °C | ekhethiweyo |
HDR-30-24 | 30W/1.5A IsiKhokelo sohlobo lukaloliwe 24V DC unikezelo lwamandla, jikelele 100 ukuya 240V igalelo AC, ubushushu bokusebenza-20 ~ 70 °C | ekhethiweyo |
HDR-30-24 | 30W/1.25A IsiKhokelo sohlobo lukaloliwe 24V DC unikezelo lwamandla, jikelele 100 ukuya 240V igalelo AC, ubushushu bokusebenza-20 ~ 70 °C | ekhethiweyo |
HDR-60-48 | 60W/1.25A Umzila kaloliwe uhlobo 48V DC amandla, jikelele 100 ukuya 240V igalelo AC, ubushushu bokusebenza-20 ~ 70 °C | ekhethiweyo |
HDR-150-48 | 150W/3.2A IsiKhokelo sohlobo lukaloliwe 48V DC unikezelo lwamandla, ngokubanzi 100 ukuya 240V AC igalelo, ubushushu bokusebenza-20 ~ 70°C | ekhethiweyo |